Shopping cart is empty
 
English Polski Spanish 
Search For a Manual
 

(e.g. AA-V20EG JVC, ZX-7 Sony )
PayPal 1000+ rating Secure, Encrypted Checkout.
 
Who's Online
There currently are 5914 guests online.
Categories
Information
Featured Product
Home >> TEKTRONIX >> TM 11-6625-2925-10 Owner's Manual
 
 0 item(s) in your cart 

TEKTRONIX TM 11-6625-2925-10
Owner's Manual


Tweet about this product and get $1.00 of store credit for instant use!
  • Download
  • PDF Format
  • Complete manual
  • Language: English
Price: $4.99

Description of TEKTRONIX TM 11-6625-2925-10 Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file after You purchase it.

Owner's Manual ( sometimes referred to as User's Guide or User's Manual ) contains information on how to use Your device. After placing order we'll send You download instructions on Your email address.

The manual is available in languages: English

Not yet ready
You must purchase it first

Customer Reviews
There are currently no product reviews.
Other Reviews
 RX-505VLTN JVC Owner's Manual by John Heizer;
Absolutely perfect! I've been trying to understand how to use all or at least some of the features of the receiver and especially the remote.
 PM2521 PHILIPS Owner's Manual by David Jesson;
Copy of genuine owners/operators manual, very useful
 RDB365D CLARION Owner's Manual by Tina Whisnant;
The manual was a perfect match and was exactly what I was looking for. I'm very satisfied with my purchase.
 CXNA10 AIWA Owner's Manual by Roberta Barr;
Thank you for having the manual I needed for an older model Aiwa stero I had found on Ebay --- I wanted the Aiwa because I had tapes and cd's but I did not have a manual as to how to operate the system... I found what I needed and it has enabled me to set the system up for my enjoyment.
 S310 JBL Owner's Manual by Jos Vallen;
I wished detailed information of the JBL S310 and here I found it! Very happy with the service from this site!

Text excerpt from page 27 (click to view)
TM 11-6625-2925-10/T0 33A1-10-242

Risetime Measurements Risetime measurements employ basically the same techniques as time-duration measurements. The main difference is the points between which the measurement is made. The following procedure gives the basic method of measuring risetime between the 10% and 90% points of the waveform. Falltime can be measured in the same manner on the trailing edge of the waveform. 1. Connect the signal to be displayed to the input of the Amplifier plug-in unit. 2. Set the Vertical and Horizontal Mode switches on the oscilloscope to display the plug-in units used. 3. Set the Volts/Division switch and the Variable Volts/ Division control of the Amplifier plug-in unit to produce a signal an exact number of divisions in amplitude. 4. Center the display about the center horizontal graticule line with the Amplifier plug-in unit Position control. 5. Set the MAIN TRIGGERING controls to obtain a stable display. 6. Set the TIME/DIV OR DLY TIME switch to the fastest sweep rate that displays less than 8 divisions between the 10% and 90% points on the waveform. 7. Determine the 10% and 90% points on the rising portion of the waveform. The figures given in Table 2-1 are for the points 10% up from the start of the rising portion and 10% down from the top of the rising portion (90% point).

Example: Assume that the horizontal distance between the 10% and 90% points is 4 divisions (see figure 2-8) and the TIME/DIV OR DLY TIME switch is set to 20 ns. Applying the time duration formula to risetime: Time Duration = (Risetime) horizontal distance (divisions) TIME/DIV OR x DLY TIME setting

Substitute the given values: Risetime = 4 x 20 nanoseconds = 80 nanoseconds

TABLE 2-1 Risetime Measurements
Vertical display (divisions) 4 5 6 7 8 10% and 90% points (divisions) 0.4 and 3.6 0.5 and 4.5 0.6 and 5.4 0.7 and 6.3 0.8 and 7.2 Divisions vertically between 10% and 90% points 3.2 4.0 4.8 5.6 6.4

Figure 2-8. Measuring risetime.
Delayed Sweep Measurements The delayed sweep mode can be used to make accurate time measurements. The following measurement determines the time difference between two pulses displayed on the same trace. This application may also be used to measure time difference from two different sources (dual-trace) or to measure time duration of a single pulse. 1. Connect the signal to be displayed to the Amplifier plug-in unit. 2. Set the Vertical and Horizontal Mode switches on the oscilloscope to display the plug-in units used. 3. Set the Volts/Division switch of the Amplifier plug-in unit to produce a display about 4 divisions in amplitude. 4. Adjust the MAIN TRIGGERING controls for a stable display.

8. Measure the horizontal distance between the 10% and 90% points. Be sure the VARIABLE control is set to CAL. 9. Multiply the distance measured in step 8 by the setting of the TIME/DIV OR [)LY TIME switch.

2-14

You might also want to buy

$4.99

SX-K700 TECHNICS
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

CJ-V51 PIONEER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

GRAND PRIX ELECTRONIC 754 BECKER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

SX-PR602 TECHNICS
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

EV-S1000E SONY
Owner's Manual

Complete owner's manual in digital format. The manual will be available for download as PDF file aft…

$4.99

GRAND PRIX ELECTRONIC 780 BECKER
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

AG7330 PANASONIC
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…

$4.99

EVO-9850 VOLUME 1 SONY
Service Manual

Complete service manual in digital format (PDF File). Service manuals usually contains circuit diagr…
>
Parse Time: 0.56 - Number of Queries: 135 - Query Time: 0.252